Super-small needle technology for the brain

(Nanowerk News) Microscale needle-electrode array technology has enhanced brain science and engineering applications, such as electrophysiological studies, drug and chemical delivery systems, and optogenetics.
However, one challenge is reducing the tissue/neuron damage associated with needle penetration, particularly for chronic insert experiment and future medical applications. A solution strategy is to use microscale-diameter needles (e.g., <5 µm) with flexible properties. However, such physically limited needles cannot penetrate the brain and other biological tissues because of needle buckling or fracturing on penetration.
high-aspect-ratio microneedles penetrating brain tissue
This image shows flexible high-aspect-ratio microneedles penetrating brain tissue. (Image: Toyohashi University of Technology)
A research team in the Department of Electrical and Electronic Information Engineering and the Electronics-Inspired Interdisciplinary Research Institute (EIIRIS) at Toyohashi University of Technology has developed a methodology to temporarily enhance the stiffness of a long, high-aspect-ratio flexible microneedle (e.g., <5µm in diameter and >500µm in length), without affecting the needle diameter and flexibility in tissue. This has been accomplished by embedding a needle base in a film scaffold, which dissolves upon contact with biological tissue. Silk fibroin is used as the dissolvable film because it has high biocompatibility, and is a known biomaterial used in implantable devices ("Dissolvable Base Scaffolds Allow Tissue Penetration of High-Aspect-Ratio Flexible Microneedles").
"We investigated preparation of a silk base scaffold for a microneedle, quantitatively analyzed needle stiffness, and evaluated the penetration capability by using mouse brains in vitro/in vivo. In addition, as an actual needle application, we demonstrated fluorescenctce particle depth injection into the brain in vivo,and confirm that by observing fluorescenctce confocal microscope" explained the first author, master's degree student Satoshi Yagi, and co-author PhD candidate Shota Yamagiwa.
The leader of the research team, Associate Professor Takeshi Kawano said: "Preparation of the dissolvable base scaffold is very simple, but this methodology promises powerful tissue penetrations using numerous high-aspect-ratio flexible microneedles, including recording/stimulation electrodes, glass pipettes, and optogenetic fibers." He added: "This has the potential to reduce invasiveness drastically and provide safer tissue penetration than conventional approaches."
Source: Toyohashi University of Technology